☀ PM Surya Ghar Registered EPC
Off-Grid Solar System

Off-Grid Solar System — Power Without the Grid

An off grid solar system runs a home, farmhouse or site entirely on its own — panels charge a battery bank by day, and an off-grid inverter supplies power day and night with no connection to the electricity grid. It is the right choice where the grid does not reach or is so unreliable it cannot be counted on: forest-edge homesteads in Dindori or Kondagaon, farmhouses, field offices, telecom and pump sites. Sunvera Energy designs off-grid systems from 1 kW to 10 kW for Madhya Pradesh and Chhattisgarh; because the battery must carry every night, sizing it correctly is what decides cost and reliability.

When off-grid is the right answer

SituationBest choice
No electricity connection and none plannedOff-grid
Connection exists but supply comes a few hours a dayHybrid (or off-grid if the grid is near-useless)
Stable connection, occasional short cutsOn-grid
Farm irrigation onlySolar water pump (off-grid by design)
Temporary site — construction camp, field officePortable off-grid

Off-grid makes sense when bringing a grid line is impossible or very expensive, or when the existing supply is so poor that the house effectively runs on kerosene and a diesel set. If your connection works most of the day, a hybrid system gives backup and still earns net-metering credits and the subsidy.

Sizing an off-grid system — the load list

Off-grid sizing starts with a list of what must run and for how long. Each appliance's wattage × hours per day gives watt-hours; the total is the daily energy the system must deliver.

ApplianceWattsHours/dayWh/day
8 LED lights8 × 9 W6432
3 ceiling fans (BLDC)3 × 30 W10900
TV + set-top box80 W4320
Refrigerator (efficient)≈ 1,000 Wh/day241,000
Phone/laptop charging, Wi-Fi——250
1 HP water pump750 W1750
Total≈ 3,650 Wh

For about 3.65 kWh a day, roughly 1.5–2 kW of panels (about 4–5 units a day per kW in MP and CG, less system losses) and a battery able to deliver the night's share plus a reserve are needed. Choosing BLDC fans and efficient appliances shrinks the whole system — often the most cost-effective saving in off-grid design.

Batteries — autonomy, chemistry and life

Autonomy is how many days the battery can carry the load with little sun. One day is the minimum; two is safer for the monsoon months. Chemistry matters: lithium iron phosphate (LFP) batteries cost more up front but deliver 80–90 per cent of their capacity, last 4,000–6,000 cycles and need no maintenance; tubular lead-acid batteries cost less but should only be discharged to about 50 per cent, last 1,200–1,500 cycles and need distilled-water topping. Over ten years LFP is usually cheaper per unit delivered. Sunvera recommends LFP for most off-grid homes and tubular batteries only where the budget is very tight and someone can maintain them.

Off-grid solar price guide (2026)

SystemDaily energyBatterySuitsInstalled price
1 kW≈ 3–3.5 kWh2.5–5 kWhLights, fans, TV, charging, small fridge₹1,00,000–1,40,000
2 kW≈ 6–7 kWh5–7.5 kWhAbove + 1 HP pump, more fans₹1,80,000–2,40,000
3 kW≈ 9–10 kWh7.5–10 kWhFarmhouse with pump and fridge₹2,80,000–3,50,000
5 kW≈ 15–17 kWh10–15 kWhLodge, field office, small clinic₹4,50,000–6,00,000

Prices include Waaree, Adani or Tata panels, off-grid inverter with MPPT charge controller, LFP battery bank (tubular on request), structure, cabling, protection, earthing, installation and commissioning. There is no DISCOM paperwork and no PM Surya Ghar subsidy; agricultural pumps have their own PM-KUSUM route.

Components of an off-grid system

  • Panels — Waaree, Adani or Tata modules sized so that even a short winter day refills the battery.
  • Off-grid inverter with MPPT charge controller — converts battery DC to household AC and charges the battery at the panels' maximum power point; pure sine-wave output so fans, fridges and electronics run as on mains power.
  • Battery bank — LFP with a battery management system, or tubular lead-acid, sized for the night plus autonomy days.
  • Optional generator or grid input — many off-grid inverters accept a generator or an occasional grid supply to top up the battery after long cloudy spells.
  • Protection — DC breakers and fuses between panels, battery and inverter, surge protection, earthing and a lightning arrester.

Because the system has no grid to fall back on, component quality matters even more than on an on-grid system: an undersized cable or a weak battery shows up as an unexpected blackout. Every Sunvera off-grid proposal lists each component by make and model.

Living off-grid

An off-grid system rewards a little attention. Use heavy loads — the pump, the washing machine, ironing — at midday when the panels are strongest, so they run from the sun rather than the battery. Keep panels clean, especially in the dry season. Watch the battery level on the inverter display or app; if it is often low by morning, a load has crept up or the battery is ageing. Sunvera's AMC includes a yearly check of battery health, connections and charge settings. To size a system, send your appliance list or a short description of the site to +91 77103 07937.

Frequently Asked Questions

Get a free site survey

Written generation estimate, exact price after subsidy and bank-finance options — no obligation.