☀ PM Surya Ghar Registered EPC
Commercial solar

Solar for Shops & Showrooms

Solar for shops works because a shop's electricity is used at the most expensive time and rate: air-conditioning, display lighting and billing systems run through business hours on a commercial tariff of ₹8–11 a unit. Sunvera Energy installs 5–15 kW rooftop systems for showrooms, clothing and jewellery stores, mobile and electronics shops, pharmacies, supermarkets and restaurants across Madhya Pradesh and Chhattisgarh. A 10 kW system costs about ₹5.5–6 lakh, saves around ₹1.2–1.3 lakh a year, and is used almost entirely inside the shop while it is open.

A shop's electricity, hour by hour

A typical showroom in Shivpuri's Sadar Bazaar, Gwalior's Maharaj Bada or Bilaspur's Gol Bazaar opens around 10 am, switches on display lights and two or three air-conditioners, runs the billing counter and CCTV, and closes at 8–9 pm. From noon to 5 pm — the hottest hours — the ACs work hardest. A rooftop system produces most between 10 am and 4 pm, which covers the bulk of that daytime load directly. The evening hours after sunset are covered by net-metering credits from midday exports, so the system offsets most of the bill even though the shop stays open after dark.

Sizes, costs and savings

Shop typeTypical systemInstalled costMonthly generationAnnual saving at ₹9/unit
Small shop, fans + 1 AC5 kW≈ ₹3,00,000600–650 units≈ ₹65,000–70,000
Showroom, 2–4 ACs, display lighting10 kW₹5,50,000–6,00,0001,200–1,250 units≈ ₹1.3 lakh
Supermarket or multi-floor store, refrigeration15–25 kW₹8–13.5 lakh1,800–3,100 units≈ ₹2–3.3 lakh
Restaurant or sweet shop10–20 kW₹5.5–10.5 lakh1,200–2,500 units≈ ₹1.3–2.7 lakh

Prices include Waaree, Adani or Tata panels, inverter, structure, cabling, protection, installation, commissioning and DISCOM net-metering paperwork. The right size comes from twelve months of bills; Sunvera does not size to the roof if the load is smaller.

Shared roofs in market buildings

Many shops sit on the ground floor of a building with other owners or tenants above, and the roof belongs to someone else or to everyone. The solutions are practical: a written NOC from the roof owner or building association allotting a defined area; an elevated structure so the roof stays usable for tanks and access; and a cable route from the roof to the shop's own meter. Where the shop is rented, the agreement should say who owns the system if the tenancy ends — panels and inverter can be moved, at a cost. Sunvera helps draft the NOC wording and plans the cable route at the survey.

Domestic or commercial connection?

Most shops are on a non-domestic (commercial) connection. These can be net-metered up to their sanctioned load and benefit from the high tariff saved, but do not receive the PM Surya Ghar subsidy; the business can claim accelerated depreciation instead. Some small shops attached to a house run on the home's domestic connection — in that case the system is a residential installation and the household can claim the subsidy of up to ₹78,000, provided the connection is in the applicant's name. The survey checks which applies before quoting.

Simple ways to save more

  • Pre-cool before noon. Set ACs to 24–26 °C and let them run from late morning when solar output is rising.
  • Switch to LED display lighting if not done already — it often halves the lighting load.
  • Keep doors closed on air-conditioned floors; an open shopfront can double AC consumption.
  • Clean panels every one to two weeks in the dry season — market dust settles quickly.
  • Check the app weekly; a sudden drop usually means dirt, shade from a new hoarding, or a tripped breaker.

Restaurants, sweet shops and refrigeration

Food businesses add a different load profile: deep freezers, display chillers, cold rooms, kitchen exhausts and in sweet shops sometimes electric ovens and mixers. Refrigeration runs around the clock, but its consumption rises sharply in the afternoon heat, exactly when panels generate most. A 10–20 kW system on a restaurant or sweet shop roof therefore keeps self-consumption high, and the evening dining rush is covered by net-metering credits from the day. Kitchen exhaust outlets are kept clear of the array, because grease-laden air soils panels quickly; the AMC schedules cleaning accordingly. For businesses that lose stock when power fails, a small hybrid section can keep chillers and billing systems running through short cuts.

Installation without closing the shop

Rooftop work is done on the roof, not inside the shop, so business continues as normal. Material is brought up early in the morning or after closing time in busy markets, and the electrical tie-in to the shop's distribution board takes under an hour, scheduled before opening or on the weekly holiday. A 5–10 kW system is usually installed in one to three days. The DISCOM inspection and net meter follow within a few weeks; Sunvera prepares the application and attends the inspection.

Where Sunvera serves shops

Market areas across 22 districts of Madhya Pradesh and Chhattisgarh — Sadar Bazaar and Court Road in Shivpuri, Maharaj Bada and City Centre in Gwalior, Hat Road in Guna, Station Road in Shahdol, Gol Bazaar and Vyapar Vihar in Bilaspur, and town markets from Balaghat to Korba — from offices at Pichhore, Gwalior, Balaghat and Bilaspur. Send twelve months of bills and a photo of the roof to +91 77103 07937 for a sized proposal.

Frequently Asked Questions

Get a free site survey

Written generation estimate, exact price after subsidy and bank-finance options — no obligation.